Model NO.
WCBX
Electricity
380/440V
Power
2.25-11kw
Transport Package
Wooden Case
Specification
CCS, ABS, GL, NK, BV, LR, DNV, RINA
Trademark
TRUST
Origin
China Jiangsu
Production Capacity
10000PCS/Month
After-sales Service:
as Per Actual
Warranty:
One Year
Product Name:
Marine Waste Sewage Treatment Plant
Application:
Seaport,Dock,Industry,Petroleum
Capacity:
10-400 Persons
Peak Load:
105-3850L/H
Marine sewage water treatment plant
Product Description
Specifications
1.CCS,ABS,BV,EC,RS,DNV,USCG,etc.
2.High quality of Marine Sewage Water Treatment Plants;
3.Automatic/manual;
4.Hot sale.
Overview:
The method of combining catalytic oxidation, ultraviolet disinfestations and sterilization is adopted in the WCBx-B Series Sewage Treatment Plant; it treats the domestic sawage of toilet from ship. Since the biomembrance is set in the aeration chamber, the chlorine adding sterilization is adopted, so compare with the products of the same kind, it has the characteristics of small cubage, light weight, compact structure and without secondary pollution. The discharged water after the treatment of the device has reached the effuent standard stipulated internationally, and it accords with the requirement of resolution MEPC.159(55) of International Marine Organization Environmental Protcetion Commission, and International Waste Fluid Effluent Standard.
WCBx-B Series Sewage Treatment Plant consists of 5 watertight tanks. These 5 tank respectively are a sewage tank, first-stage contact oxidation tank, second-stage contact oxidation tank, a settlement tank and a catchment tank.
Classification society certificates:
CCS,ABS,BV,EC,RS,DNV,USCG,etc.
Description:
1. After the sewage from toilet crushed completely flows into he sewage tank by the way of nature inflow to contact oxidation tank to aerate by air pump, and to contact with biofilms by a cerain velociy flowing through fillings.
2. The organic pollutant will be digested by biofilms and CO2 and water are generated.
3. After further treatment of the biofilm in the second contact tank .When the catchment tank collects a certain amount of liquid, the process pump is started and the liquid is put into the ultrafilter to filter the slag by the water pump The ultraviolet sterilizing plant kills the bacteria in the fluid, and treated water is discharged overboard as an effluent.
4. The sludge in the settlement tank will be retured to first-stage contact tank in airlift device , which will cause a certain back flow ratio.
Technology Parameter
Packaging & Delivery
Related products



Product Description
Specifications
1.CCS,ABS,BV,EC,RS,DNV,USCG,etc.
2.High quality of Marine Sewage Water Treatment Plants;
3.Automatic/manual;
4.Hot sale.
Overview:
The method of combining catalytic oxidation, ultraviolet disinfestations and sterilization is adopted in the WCBx-B Series Sewage Treatment Plant; it treats the domestic sawage of toilet from ship. Since the biomembrance is set in the aeration chamber, the chlorine adding sterilization is adopted, so compare with the products of the same kind, it has the characteristics of small cubage, light weight, compact structure and without secondary pollution. The discharged water after the treatment of the device has reached the effuent standard stipulated internationally, and it accords with the requirement of resolution MEPC.159(55) of International Marine Organization Environmental Protcetion Commission, and International Waste Fluid Effluent Standard.
WCBx-B Series Sewage Treatment Plant consists of 5 watertight tanks. These 5 tank respectively are a sewage tank, first-stage contact oxidation tank, second-stage contact oxidation tank, a settlement tank and a catchment tank.
Classification society certificates:
CCS,ABS,BV,EC,RS,DNV,USCG,etc.
Description:
1. After the sewage from toilet crushed completely flows into he sewage tank by the way of nature inflow to contact oxidation tank to aerate by air pump, and to contact with biofilms by a cerain velociy flowing through fillings.
2. The organic pollutant will be digested by biofilms and CO2 and water are generated.
3. After further treatment of the biofilm in the second contact tank .When the catchment tank collects a certain amount of liquid, the process pump is started and the liquid is put into the ultrafilter to filter the slag by the water pump The ultraviolet sterilizing plant kills the bacteria in the fluid, and treated water is discharged overboard as an effluent.
4. The sludge in the settlement tank will be retured to first-stage contact tank in airlift device , which will cause a certain back flow ratio.
Technology Parameter
Model Parameter\ | WCBx-10B | WCBx-15B | WCBx-20B | WCBx-25B | WCBx-30B | WCBx-40B | WCBx-50B | WCBx-60B | WCBx-80B | WCBx-100B | WCBx-150B | WCBx-200B | WCBx-300B | WCBx-400B | WCBx-500B | WCBx-600B | |
Suitable number of people | 10 | 15 | 20 | 25 | 30 | 40 | 50 | 60 | 80 | 100 | 150 | 200 | 300 | 400 | 500 | 600 | |
Treatment load (m³/d) | 0.75 | 1.05 | 1.40 | 1.75 | 2.10 | 2.80 | 3.50 | 4.20 | 5.60 | 7.0 | 10.5 | 14 | 21 | 28 | 35 | 42 | |
Organic load (kg/d) | 0.35 | 0.525 | 0.70 | 0.875 | 1.05 | 1.40 | 1.75 | 2.10 | 2.80 | 3.50 | 5.25 | 7.0 | 10.5 | 14 | 17.5 | 21 | |
Discharge standard | BOD5≤25mg/l; COD≤125mg/l; TSS≤35mg/l; Coil group≤100/100ml; PH:6~8.5 | ||||||||||||||||
Process Pump | Model | 32CGW-10-20 | 2CWF-11 | ||||||||||||||
Type | Vertical type | Blade centrifugal type | |||||||||||||||
Capacity | 10 | 20 | |||||||||||||||
Motor power | 1.5 | 2.2 | |||||||||||||||
Air pump | Model | CYBW-10 | CYBW-20 | CYBW-40 | |||||||||||||
Type | Sliding vane type | ||||||||||||||||
Capacity | 10 | 20 | 40 | ||||||||||||||
Motor power | 0.37 | 0.75 | 1.5 | ||||||||||||||
Crushing pump | Model | 0.5CWF-10 | 1CWF-11 | 2CWF-11 | |||||||||||||
Type | Advanced anti-soil ultrafiltration membrane | ||||||||||||||||
Capacity | 5 | 10 | 20 | ||||||||||||||
Motor power | 1.1 | 1.5 | 2.2 | ||||||||||||||
Ultrafilter | Model | CSUF-5060 | CSUF-6050 | ||||||||||||||
Type | Advanced anti-soil ultrafiltration membrane | ||||||||||||||||
Capacity | 0.4~0.5 | 0.6~0.8 | |||||||||||||||
Sterilizer | Model | DY-UV-GL-C | DY-UV-GL-D | DY-UV-GL-E | |||||||||||||
Wavelength | 253.7 | 253.7 | 253.7 | ||||||||||||||
Power | 0.27 | 0.36 | 0.54 | ||||||||||||||
Capacity | 1.5 | 2.0 | 2.5 | ||||||||||||||
Back flushing water pressure | 0.1~0.25MPa | ||||||||||||||||
Power supply | AC 3Ph 380V/50HZ or AC 3Ph 440V/60HZ | ||||||||||||||||
Control mode | Automatic/manual |
Packaging & Delivery
Packing details | Standard export packing, or according to client's requirements. |
Delivery details | According to the order quantity. |
Related products