Hot Search: hoverboard  Steel  TBR  445/95r25  elevator  tractor  sweepers  rims  Moped  ceiling 

Negative Pressure Ambulance Van with Gasoline&Diesel&EV, Gasoline, Quality

Supplier Ruili Science and Technology Company Limited of Peking
Price $8000.00 / Piece
Availability In Stock
Mini Order:
+-
Subtotal: $8000

Purchase details

Payments:

Tax:

Tax Included 

Returns&Refunds:

Eligible for refunds within 30 days of receiving products. returns and refunds 

 
Model NO.
6540
Seats
Ambulance
Max Speed
91-110km/h
Fuel
Gasoline&Diesel&EV
Steering Position
LHD&Rhd
Size
Bus
Intelligence
NBT
Qaulity
Euro Standard
Body
Electrophoresis
Flexibility
Van Can Be Customized
Transport Package
CBU
Specification
4880*1700*2185 mm
Trademark
Chinlion
Origin
China
HS Code
8702901000
Production Capacity
10000
Standard Configuration of Negative Pressure Ambulance (Type I/Type II)
ItemVehicle ModelParameters
Vehicle DimensionsLength × width × height (mm)5470×1885×2440; 5570×1885×2440 (with rear step)
Wheelbase (mm)3110
Front/rear wheel track (mm)1635/1745
Internal Dimensions of Medical CabinLength × width × height (mm)3360X1700X1570
Weight ParametersCurb weight (kg)2150
Gross mass (kg)3380
TrafficabilityApproach angle/departure angle (°)17/18;17/17
Minimum turning diameter (m)11.7
Dynamic PerformanceMaximum speed (km/h)150
Maximum gradeability (%)≥30%
EngineEngine ModelMianyang Xinchen 4RB2
OBDStandard configuration
Emission standardChina V for light vehicle
Operating modeIn-line 4-cylinder 8-valve, variable valve timing technology
Displacement (mL)2438
Rated power (kW/rpm)102/4600~5000
Maximum torque (NŸm/rpm)210/2600~3200
TransmissionTransmission modelYancheng Zomax (ZM025A)
Fuel Tank and FuelFuel typeGasoline
Fuel tank volume (L)70
Steering SystemSteering assistHydraulic power assisted steering, pinion-and-rack type
Brake SystemType of brake systemHydraulic double-circuit vacuum boosting
Brake assist systemElectronic ABS+EBD brake assist system (ABS + braking force distribution system)
Parking brakeSide parking brake structure, with hand control acting on rear wheels
Suspension SystemFront suspension structureFront independent, torsion bar
Rear suspension structureNon-independent, steel plate, 5 springs
WheelModel195R/15C;195R/15LT
Quantity5
Number of SeatsNumber of Seats5-9

Special Configuration of Negative Pressure Ambulance (Type I/Type II)
FunctionEquipmentEquipment DescriptionQuantity Used
Alarm Lamp SystemAlarm lampStrip alarm lampOne set
Central Power Distribution SystemMultifunctional power supply control systemIt supports two power supply modes, external power supply (to be connected with utility power) and vehicle-mounted intelligent inverter power supply system, capable of automatic switching between 12 V DC and 220 V AC power supplies.One set
Medicine Cabinet SystemMedicine cabinetLight-weight environmental protection materialOne set
Oxygen cylinder cabinetLight-weight environmental protection materialOne set
Combined cabinetLight-weight environmental protection materialOne set
Medical FloorMedical floor leatherResistant to acid, alkali, fire, skidding, static electricityOne set
Specialized Medical EquipmentOxygen cylinder10LTwo sets
Sputum aspirator One set
Sphygmomanometer One set
Ultraviolet disinfection lamp One set
Oxygen supply system One set
Stretcher SystemDeluxe automatic boarding stretcher + automatic boarding platform (including shovel stretcher)Patient transferringOne set
Medical Cabin Lighting SystemWorking lamp One set
Stretcher-type Negative Pressure Isolation CabinStretcher-type Negative Pressure Isolation CabinPower supply: rated voltage of AC 220 V, 50 HZ, internal power supply DC 12 V, input power of 50 VA. Filtration power: filtration efficiency ≥99.99% for 0.3 μm particulate aerosol. Negative pressure: A negative pressure of not less than 15 Pa shall be established within 2 min when there is passenger in the ambulance. Ventilation rate: ≥75 L/min. Effective power supply duration: lithium battery power supply, ≥2 h. Noise: ≤72 dB(A).One set
Negative Pressure SystemFan systemExhaust air rate: 200 m3/h-600 m3/h, 220 V, 300 W to ensure optimal ventilation efficiency in the medical cabin, and to minimize the probability of cross infection among medical staff during the process of treating and transferring patients with infectious diseases.One set (Type II only)
Filtration systemFiltration power: filtration efficiency ≥99.99% for 0.3 μm particulate aerosol (the national standard requiring ≥99.97%). The air in the van will be discharged after bio-safety disposal.One set (Type II only)

Negative Pressure Ambulance Van with Gasoline&Diesel&EVNegative Pressure Ambulance Van with Gasoline&Diesel&EVNegative Pressure Ambulance Van with Gasoline&Diesel&EVNegative Pressure Ambulance Van with Gasoline&Diesel&EVNegative Pressure Ambulance Van with Gasoline&Diesel&EV








 
 
 
Send Message
Message Type
*Content
*Your Name  
*Tel
*Email
* Captcha  
You May Like
Related Search: Negative Pressure Ambulance Van with Gasoline&Diesel&EV Gasoline Quality Vehicles Motor Vehicles Bus City Bus