1 Basic Function
1.1Display floors number and travel direction
1.2Display "FIRE", "OVER LOAD" with photo and character.
1.3Display "NO SMOKING" with photo and character.
2 Main technology features
2.1Power supply:DC24V,power voltage range:DC12~30V
2.2Current:<85mA (including back light)
2.3Operating temperature:-20~70ºC
2.4Screen parameter:
2.4.1Color:



(STN)white text on blue background (BTN)white text on black background (BTN)yellow text on black background
2.4.2Back light: white LED service life≥50000hrs
2.4.3Active screen size: 126×95.5mm
2.4.4Brightness: 200cd/m2
2.4.5Best view angle: 6 o'clock
5.1.1Power supply and signal: Apply 3.81mm standard 16 needles G-sub single plug-connecting.
5.1.2The definition of input line:
Definition | COM | A 1 | B 1 | E 1 | F 1 | G 1 | A 2 | C 2 | G 2 | UP | DOWN | FIRE | OVERLOAD | NO SMKING | GND | +24 |
Remark: A1~G2 is the left digit of 7-segment display unit. A1~G1 is the right digit of 7-segment unit. A1 is the lowest digit and while G2 is the highest digit.