FEATURES:
Capacity 10t to 50t |
Double rocking column structure |
High sealing performance |
OIML C3 |
Alloy steel, stainless steel |
APPLICATION:
Truck scale |
Hopper Scale |
Axle-load scale |
Railway Scale |
Rated capacity | D1 | D2 | D3 | D4 | D5 | H1 | H2 | L1 | T1 | T2 | T3 |
10,15,20,25,30,40,50 | 83.5 | 64 | 44 | 48 | 76 | 150 | 200 | 149 | M8 | M8 | M16 |
SPECIFICATION: |
|
Rated capacity: 10ton to 50ton | Operating temperature range: -30 to +70ºC |
Rated output: 2.0±0.002mv/v | Maximum safe overload: 150% OF R.C |
Combined error: ±0.03% F.S | Ultimate safe overload: 200% OF R.C |
Non-repeatability: ±0.02% F.S | Recommended Excitation: 10 to 12V DC |
Non-linearity: ±0.02% F.S | Maximum Excitation: 15V DC |
Hysteresis error: ±0.02% F.S | Environment protection: IP68 |
Zero balance: ±1% F.S | Input impedance: 400±20Ω(ZSF);700±20Ω(ZSFY) |
Creep error(30minutes): ±0.02% F.S | Output impedance: 352±3Ω(ZSF);703±5Ω(ZSFY) |
Temperature effect on zero: ±0.02% F.S | Insulation resistance at 50V DC: ≥5000MΩ |
Temperature effect on output: ±0.02% F.S | Material: alloy steel(ZSF-A,ZSFY-A); Stainless Steel(ZSF-ASS,ZSFY-ASS) |
Compensated temperature range: -10 to +40ºC | Cable length: 8meter(10t),10meter(15t),12meter(20t,25t), 14meter(30t),16meter(40t,50t) Diameter: φ5mm |