Accuracy Grade
1.0G
IP Rating
IP65
Certification
CE
Customized
Customized
Flow Fluid Measured
Liquid, Air, Solid Flow
Output Signal
4-20mA, Pulse, RS485, Hart
Indicate
Flow Rate, Total Flow, Density, Temperature
Fluid Types
Two-Phase Flow, Three-Phase Flow
Sensor
Tube/Flange
Accuracy
±0.2%~±0.15%, ±0.2-0.5%
Measuring Media
Liquid
Size
Dn1.5~Dn200
Measuring Principle
Atomic Physics, Atomic Physics~@
Transport Package
Wooden Case or Carton
Trademark
U-ideal
Origin
Tianjin, China
HS Code
90261000
Production Capacity
6000 PCS/Month
Type:
Coriolis Mass Flow Meter
Structure Type:
Karman Vortex
Measuring Medium:
Gas
Output Signal Type:
Digital Type
Production Process:
SemiConductor Integrated
Material:
Stainless Steel
The coriolis force mass flow transmitter, mass flow meter working principle and application:
(1) The Coriolis force mass flowmeter can measure the mass flow rate directly, and won't be affected by the measured medium temperature, pressure, density, viscosity. But other kinds of mass flowmeter using indirect measurement method, to measure volume flow first, and then got the mass flow rate after compensation of temperature, pressure, density.
(2) The Coriolis force mass flowmeter inside have no moving parts, high reliability; Don't need Straight pipe before and after the installation.
(3) The Coriolis force mass flowmeter measurement accuracy is high, up to + 0.1%~ + 0.2% R; And wide range ratio at maximum of 1:100.
(4) The Coriolis force mass flowmeter have options of all-in-one type and split type, LCD, explosion-proof type, temperature insulating model. Can output analog signal 4~20mA, the frequency signal, the RS485 communication interface and Hart protocol at the same time.
(5) The Coriolis force mass flowmeter is suitable for various liquid, such as corrosive liquid, smudgy medium, suspension, two phase liquid (gas content in liquid <10% in volume, if air content big, please add air eliminator), etc.
High precision of CMF series of Coriolis force mass flowmeter is mainly used to measure the instantaneous mass flow rate and cumulative mass flow, instantaneous volume flow and cumulative volume flow, at the same time also can display the medium temperature, medium density or concentration. It is mainly suitable for the following industries:
(1) he Toil industry, such as diesel, gasoline, heavy oil fuel metering; Crude oil output measurement, moisture content, the single well production; Crude oil loading and unloading metering, etc.;
(2) The chemical industry, such as toluene, xylene, butanone, cyclohexanone, n-butyl alcohol, isobutyl alcohol, methylene chloride, chloroform, liquid sulfur, lactam etc;
(3) The power industry, such as heavy oil, diesel fuel oil metering, slurry density meter limestone-gypsum wet desulphurization;
(4) The food, pharmaceutical industries, such as chocolate syrup, milk, fruit juice, pharmaceuticals, BPC (bulk pharmaceutical chemicals) measurement (clamp type healthy connection type);
(5) The energy industry, such as liquefied petroleum gas, natural gas, high pressure gas metering;
(6) In other industries, such as mortar measurement of solar silicon wafer multi-line cutting machine, measurement of pulp papermaking industry, power plant desulfurization serous densimeter, fine chemical raw material proportioning, asphalt measurement, etc.
High precision CMF series of Coriolis force mass flowmeter can also be used as a densitometer, concentration meter. At the time of the flow and temperature measurement, can measure the density of the medium, the concentration of the solution and the mixing parameters such as the concentration of the two liquids respectively.
For example: syrup concentration (sugar) measurement in sugar mill, alcohol content measurement in brewery; mortar flow, temperature and density measurement of Solar silicon wafer wire cut machine; limestone slurry density measurement; red liquid concentration measurement in sewage treatment plant; Lead plant pulp density measurement; Iron ore pulp density measurement, copper plant pulp density measurement, sand (sediment) concentration measurement in sand-excavating ship, oil and water content measurement in oil field, etc
(1) Measurement medium: Liquid, gas, solid, or two phases and three phases mixed fluid
(2) Output signal:
4-20mA current signal of flow, with load resistance ≤ 500Ω
0-10kHz frequency signal of flow.
RS485 Communication protocol
Hart protocol
(3) Measurement of measuring pipe: 316L stainless steel
(4) Response time: 0.1s~5s, adjustable
(5) Explosion-proof grade: Ex(ib)II BT2-T5




(1) The Coriolis force mass flowmeter can measure the mass flow rate directly, and won't be affected by the measured medium temperature, pressure, density, viscosity. But other kinds of mass flowmeter using indirect measurement method, to measure volume flow first, and then got the mass flow rate after compensation of temperature, pressure, density.
(2) The Coriolis force mass flowmeter inside have no moving parts, high reliability; Don't need Straight pipe before and after the installation.
(3) The Coriolis force mass flowmeter measurement accuracy is high, up to + 0.1%~ + 0.2% R; And wide range ratio at maximum of 1:100.
(4) The Coriolis force mass flowmeter have options of all-in-one type and split type, LCD, explosion-proof type, temperature insulating model. Can output analog signal 4~20mA, the frequency signal, the RS485 communication interface and Hart protocol at the same time.
(5) The Coriolis force mass flowmeter is suitable for various liquid, such as corrosive liquid, smudgy medium, suspension, two phase liquid (gas content in liquid <10% in volume, if air content big, please add air eliminator), etc.
High precision of CMF series of Coriolis force mass flowmeter is mainly used to measure the instantaneous mass flow rate and cumulative mass flow, instantaneous volume flow and cumulative volume flow, at the same time also can display the medium temperature, medium density or concentration. It is mainly suitable for the following industries:
(1) he Toil industry, such as diesel, gasoline, heavy oil fuel metering; Crude oil output measurement, moisture content, the single well production; Crude oil loading and unloading metering, etc.;
(2) The chemical industry, such as toluene, xylene, butanone, cyclohexanone, n-butyl alcohol, isobutyl alcohol, methylene chloride, chloroform, liquid sulfur, lactam etc;
(3) The power industry, such as heavy oil, diesel fuel oil metering, slurry density meter limestone-gypsum wet desulphurization;
(4) The food, pharmaceutical industries, such as chocolate syrup, milk, fruit juice, pharmaceuticals, BPC (bulk pharmaceutical chemicals) measurement (clamp type healthy connection type);
(5) The energy industry, such as liquefied petroleum gas, natural gas, high pressure gas metering;
(6) In other industries, such as mortar measurement of solar silicon wafer multi-line cutting machine, measurement of pulp papermaking industry, power plant desulfurization serous densimeter, fine chemical raw material proportioning, asphalt measurement, etc.
High precision CMF series of Coriolis force mass flowmeter can also be used as a densitometer, concentration meter. At the time of the flow and temperature measurement, can measure the density of the medium, the concentration of the solution and the mixing parameters such as the concentration of the two liquids respectively.
For example: syrup concentration (sugar) measurement in sugar mill, alcohol content measurement in brewery; mortar flow, temperature and density measurement of Solar silicon wafer wire cut machine; limestone slurry density measurement; red liquid concentration measurement in sewage treatment plant; Lead plant pulp density measurement; Iron ore pulp density measurement, copper plant pulp density measurement, sand (sediment) concentration measurement in sand-excavating ship, oil and water content measurement in oil field, etc
(1) Measurement medium: Liquid, gas, solid, or two phases and three phases mixed fluid
(2) Output signal:
4-20mA current signal of flow, with load resistance ≤ 500Ω
0-10kHz frequency signal of flow.
RS485 Communication protocol
Hart protocol
(3) Measurement of measuring pipe: 316L stainless steel
(4) Response time: 0.1s~5s, adjustable
(5) Explosion-proof grade: Ex(ib)II BT2-T5
Titles | Technical Specifications |
Mass flow accuracy | ±[0.2% +(zero stability /flow rate×100%)] |
Mass flow repeatability | ±(1/2)×[0.2%+(zero stability /flow rate×100%)] |
Density range | 0.2 g/cm 3 ~3.5g/cm 3 |
Density accuracy | ±0.002g/cm 3 |
Temperature range | -60ºC~+200ºC |
Temperature accuracy | ±1ºC |
Output of current loop | 4mA~20mA |
Output of frequency/pulse | 0Hz~10kHz |
Contact rating of a Batch Control relay | 24V/0.1A |
Contactor form | normal open |




Specs | Line Sizes (mm) | Flow Range (t/h) | Calibration Range (t/h) | Max. Tube Pressure (MPa) | Zero Stability (t/hr) | Velocity (h m/t s) |
DN1 | 1 | 0~0.04 | 0.004~0.04 | 30.0 | 0.000008 | 353.7 |
DN3 | 3 | 0~0.35 | 0.035~0.35 | 30.0 | 0.000067 | 39.3 |
DN6 | 6 | 0~0.7 | 0.07~0.7 | 30.0 | 0.00016 | 19.65 |
DN10 | 10 | 0~1.2 | 0.12~1.2 | 30.0 | 0.0002 | 4.912 |
DN15 | 15 | 0~6.4 | 0.64~6.4 | 4.0 | 0.0011 | 2.183 |
DN25 | 25 | 0~16 | 1.6~16 | 4.0 | 0.002 | 0.902 |
DN40 | 40 | 0~40 | 4~40 | 4.0 | 0.003 | 0.334 |
DN50 | 50 | 0~65 | 6.5~65 | 4.0 | 0.006 | 0.197 |
DN80 | 80 | 0~160 | 16~160 | 2.5 | 0.01 | 0.0873 |
DN100 | 100 | 0~250 | 25~250 | 2.5 | 0.015 | 0.0544 |
DN150 | 150 | 0~550 | 55~550 | 2.5 | 0.03 | 0.0239 |
Send Message