Model NO.
MP-7
Type
Gas Sensor
Conductivity Type
Non-conductivity Type
Output Signal Type
Analog Type
Production Process
Ceramics
Material
Metal
IP Rating
IP20
Sensitivity
High
Certification
CE
Customized
Customized
Sensor Type
Semiconductor Flat Surfaced
Detection Gas
Carton Monoxide
Detection Range
50-1000ppm
Trademark
DESON
Transport Package
Cartons
Specification
50-1000ppm
Origin
China
MP-7 adopts advanced planar construction production technics, using MOS material formed by micro AL2O3 ceramic tube and heater, electro-down-lead be fetched out, and are fixed into a metal base and cover. Adopting low and high temperature circling detection: when low temperature (VH=1.5V), it detects CO, Conductance of sensor bigger along with CO concentration in air; When high temperature(VH=5.0V), clean other gases, using simple circuit could change the conductance, change it to be output signal which relatively to the gas concentration.
Character
* High Sensitivity to CO
* Mini Size
* Fast response and resume character
* Excellent Stability and long life
Application
* They are used in gas leakage detecting equipment in family, industry and commercial field, fire resistance/ safety detection system.
* CO gas leakage alarm and detector
Character
* High Sensitivity to CO
* Mini Size
* Fast response and resume character
* Excellent Stability and long life
Application
* They are used in gas leakage detecting equipment in family, industry and commercial field, fire resistance/ safety detection system.
* CO gas leakage alarm and detector
Technical indicators
Product number | MP-7 | ||
product type | Flat Surfaced Semiconductor gas sensor | ||
Standard package | Bakelite , plastic | ||
Detection of gasOzone | Carton Monoxide | ||
Detection of concentration | 50-1000ppm | ||
Standard circuit conditions | Circuit voltage | VC | ≤24V DC |
Heating voltage | VH | 5.0V ± 0.1V ACorDC | |
Load Resistance | RL | Adjustable | |
Characteristics of Gas Sensors under Standard Test Conditions | Heating resistance | RH | 29 ± 3Ω (room temperature) |
Heating power consumption | PH | ≤900mW | |
The output voltage | Vs | 2.5-4.0V (in 125ppm) | |
Sensitivity | S | Rs (in air) / Rs (125 ppm ) ≥5 | |
Concentration slope | Α | ≤0.6 (R300ppm/ R125ppmalcohol) | |
Standard test conditions | temperature humidity | 20 ° C ± 2 ° C; 55% ± 5% RH | |
Standard test circuit | VC: 5.0V ± 0.1V VH: 5.0V ± 0.1V | ||
Warm up time | Not less than 48 hours |
Note: Product parameters are subject to change without notice