Model NO.
319I2C
Wiring Type
Four-Wire
Measuring Medium
Liquid
IP Rating
IP68
Certification
RoHS
Customized
Customized
Transport Package
Foam+Carton
Specification
dia. 19mm
Trademark
Runpaq
Origin
China
Type:
Piezoresistive Pressure Sensor
Component:
SemiConductor Type
For:
Diffused Silicon Pressure Transmitter
Output Signal Type:
Analog Type
Production Process:
Integration
Material:
Stainless Steel
Digital pressure sensor I2C, piezoresistive, 0-1000 barg
Digital Pressure Sensor can transfer the measurement signals of pressure and liquid level to I2C digital output. With the fast and accurate interface, the 319-I2C is used to build an Internet of Things using a microcontroller. It can read data and control power on and off to reduce power consumption through microprocessor operation.
319-I2C Digital Pressure Sensor is available ranges from -100KPa to 100MPa.
Technical parameters
Remarks: Range -100KPa~100MPa; *The typical value of 0~10KPa and 0~20KPa's zero; temperature drift and sensitivity temperature drift is 0.4%FS@25ºC, max value is 1.6%FS@25ºC
Standard range
Notes: G for Gauge pressure; A for Absolute pressure; D for Differential pressure; S for Sealed gauge.
Data Measurement & Communication Sequence
For read and write operations, the master device commands to start, and sends an ACK (acknowledgement) as a slave device to indicate success. The factory address of the slave device is 0x28, and the communication sequence is shown as below


Drawing & wiring diagram
Dimensions

Model selections
Note: 1. Extremely attention must be paid to sensor installation process to avoid any miss conduction that affect the sensor performance,
2. please protect the diaphragm and the compensated board carefully to prevent any damage. 3. Please contact us if your requested working
temperature lower than -20ºC
Digital Pressure Sensor can transfer the measurement signals of pressure and liquid level to I2C digital output. With the fast and accurate interface, the 319-I2C is used to build an Internet of Things using a microcontroller. It can read data and control power on and off to reduce power consumption through microprocessor operation.
319-I2C Digital Pressure Sensor is available ranges from -100KPa to 100MPa.
Application | Key features |
• Industrial process control • Level measurement • Gas, liquid pressure measurement • Pressure checking meter • Pressure calibrator • Liquid pressure system and switch • Cooling equipment & A/C system • Aviation and navigation inspection • Pneumatics and hydraulics systems | • Digital compensation for sensor offset, sensitivity, temperature drift and nonlinearity • 32-bit customer ID field for module traceability • Digital output of temperature and pressure in I2C bus mode • Fast power-on to data output response: 3ms • Low power consumption, sleep mode operation, as low as 5 uA, current consumption depends on the programmed sampling rate • Operating temperature: -40°C to + 85°C • Wide supply voltage capability: 3.3V/5V |
Construction performance | Electric & Environment Performance |
Diaphragm: Stainless Steel 316L Housing: Stainless Steel 316L Pressure leading tube: Stainless Steel 316L O Ring: Φ16*1.8mm (nitrile rubber or viton) Measuring Medium: Which is compatible with SS316L, viton, nitrile rubber Packing Medium: Silicon Oil Net weight: 20-30g | Power supply: 5±0.1Vdc; 3.3±0.1Vdc; Insulation Resistance: 500MΩ@500VDC Overpressure: 1.5~3 times FS Vibration (20~500Hz): 20G Storage Temp.: -40~+125ºC Operating Temp.: -40~+85ºC Compensation Temp.: 0~50ºC; -10~80ºC @ 0~70(7kPa,20 kPa,35 kPa |
Technical parameters
Parameters | Type | Max. | Unit |
Non-linearity | 0.2 | 0.5 | %FS |
Hysteresis | 0.05 | 0.1 | %FS |
Repeatability | 0.05 | 0.1 | %FS |
Zero output | +/-1 | +/-2 | mV DC |
FS output | 100 | - | mV DC |
Input/Output impedance | 2.6 | 3.8 | k Ω |
Zero Temp. drift* | +/- 0.15 | +/- 0.8 | %FS,@25ºC |
Sensitivity Temp. drift* | +/-0.2 | +/-0.7 | %FS,@25ºC |
Standard range
Range | Overload | Output/F.S (mV) | Typical value(mV) | Pressure type |
0~10KPa | 300% | 35~60 | 45 | G |
0~20KPa | 300% | 70~110 | 90 | G/A |
0~35KPa | 300% | 55~80 | 70 | G/A/D |
0~70KPa | 300% | 55~80 | 60 | G/A/D |
0~100KPa | 300% | 60~85 | 75 | G/A/D |
0~200KPa | 300% | 60~85 | 75 | G/A/D |
0~400KPa | 300% | 60~80 | 70 | G/A/D |
0~600KPa | 200% | 90~120 | 100 | G/A/D |
0~1.0MPa | 200% | 125~185 | 150 | G/A/D |
0~1.6MPa | 200% | 80~120 | 100 | G/A/D |
0~2.0MPa | 200% | 50~70 | 60 | G/A/D |
0~3.5MPa | 200% | 100~120 | 110 | G/A/D |
0~7.0MPa | 200% | 120~150 | 135 | G/A |
0~10MPa | 200% | 180~230 | 200 | G/A |
0~25MPa | 150% | 140~170 | 150 | S |
0~40MPa | 150% | 230~280 | 250 | S |
0~60MPa | 150% | 100~160 | 130 | S |
0~100MPa | 150% | 100~150 | 120 | S |
Data Measurement & Communication Sequence
For read and write operations, the master device commands to start, and sends an ACK (acknowledgement) as a slave device to indicate success. The factory address of the slave device is 0x28, and the communication sequence is shown as below


Drawing & wiring diagram
Dimensions

Model selections

2. please protect the diaphragm and the compensated board carefully to prevent any damage. 3. Please contact us if your requested working
temperature lower than -20ºC
Send Message